Syncronis HPLC

Consumibles de Cromatografía › Columnas HPLC / HPLC-MS

Syncronis HPLC

Syncronis HPLC

Consultar por WhatsApp

Descripción detallada

Syncronis aQ HPLC Columns

Consistent, predictable separations, Column after column, time after time

Stability in 100% aqueous mobile phase

Outstanding reproducibility

Highly pure, high surface area silica

Highly inert towards basic compounds

Rigorously tested to ensure quality

 

 Specifications

  \"\"

 Stability in 100% aqueous mobile phase

In comparison to a conventionally endcapped C18, the Thermo Scientific™ Syncronis™

aQ polar end-capped C18 stationary phase exhibits superior stability towards aqueous mobile phase.

Syncronis aQ shows no degradation in performance after 100 injections in a buffered 100% aqueous eluent.

\"\"

Application: Amoxicillin and Potassium Clavulanate (USP)

 \"\"

 Syncronis C8 HPLC Columns

 Consistent, predictable separations,Column after column, time after time

  Outstanding reproducibility

  Highly pure, high surface area silica

  Less hydrophobic than C18

   Double endcapped for extra surface coverage

   Highly inert towards basic compounds

   Rigorously tested to ensure quality

 Specifications

 \"\"

 Less retentive than C18

Thermo Scientific™ Syncronis™ C8 HPLC columns are less hydrophobic than the C18 and are therefore particularly useful where the lesser degree of hydrophobicity is needed in order to successfully retain compounds of interest. Syncronis C8 HPLC columns can also be used where it is desirable to elute compounds more quickly than with a C18 HPLC column.

 

 Application: Fenoprofen (USP)

 \"\"

  Application: Uron Herbicides

\"\"

 

Syncronis C18 HPLC Columns

Consistent, predictable separations, Column after column, time after time

  Outstanding reproducibility \"\"

  Highly pure, high surface area silica

  High carbon load for increased retention

  Double endcapped for extra surface coverage

 Highly inert towards basic compounds

 Rigorously tested to ensure quality

  Specifications

\"\"

Outstanding column to column reproducibility

When developing a new method, one of the most important goals for the chromatographer is to achieve a consistent, reproducible separation. The selection of a highly reproducible HPLC column is essential if this goal is to be attained.

Thermo Scientific™ Syncronis™ C18 HPLC columns show excellent column to column reproducibility, as illustrated here by the analysis of zidovudine using five separate columns.

The reproducibility in terms of retention time and peak area is less than or equal to 0.5%, column to column. This indicates that the columns are well packed.

The variation in peak area is 0.27%, which is important for quantitation of analytes.

Syncronis C18 HPLC columns achieve this goal, starting from the highly pure, high surface area silica and dense bonding, all controlled and characterized through the use of rigorous testing.

New, enhanced, automated column packing methods drive consistency even further and every column is individually tested to ensure that it meets the required specifications.

These extensive testing and quality control procedures ensure the delivery of a consistent product, column after column.

  \"\"

 

 

 

 

 

 

 

 

 

 

 

 

 

 \"\"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 